Loading...
HomeMy WebLinkAbout5-19-25 ENR PacketAGENDA CITY OF MAPLEWOOD ENVIRONMENTAL AND NATURAL RESOURCES COMMISSION Monday, May 19, 2025 7:00 p.m. Maplewood City Council Chambers 1803 County Road B East 1. Call to Order 2. Roll Call 3. Approval of Agenda 4. Approval of Minutes a. April 21, 2025 5. Unfinished Business a. St. Paul Police Training Facility, 2621 Linwood Avenue East - Wetland Buffer Variance 6. New Business 7. Visitor Presentations 8. Commissioner Presentations 9. Staff Presentations (oral reports) a. New ENR Commission Meeting Schedule – Second Wednesday of the Month at 6 p.m. beginning June 11, 2025 b. Spring Clean Up Summary – Saturday, May 3 c. Waterfest – Saturday, May 31, 11 a.m. to 4 p.m., Lake Phalen Park d. Ramsey County Environmental Center Tour – Monday, July 21, 6 to 7:30 p.m. e. ENR Commission Calendar 10. Adjourn MINUTES CITY OF MAPLEWOOD ENVIRONMENTAL AND NATURAL RESOURCES COMMISSION Monday, April 21, 2025 7:00 P.M. 1.CALL TO ORDER Chairperson Lates called a meeting of the Environmental and Natural Resources Commission to order at 7:02 p.m. 2.ROLL CALL Rebecca Bryan, Commissioner Absent Joanne Cryer, Commissioner Present Nancy Edwards, Vice-Chairperson Present Benjamin Guell, Commissioner Present David Lates, Chairperson Present Ted Redmond, Commissioner Absent Wes Saunders-Pearce, Commissioner Present Staff Present Shann Finwall, Sustainability Coordinator 3.APPROVAL OF AGENDA Commissioner Guell moved to approve the April 21, 2025, Environmental and Natural Resources Commission meeting agenda. Seconded by Commissioner Edwards. Ayes – All The motion passed. 4.APPROVAL OF MINUTES a.March 17, 2025 Chairperson Lates moved to approve the March 17, 2025, Environmental and Natural Resources Commission meeting minutes as written. Seconded by Commissioner Guell. Ayes – All The motion passed. 5.NEW BUSINESS a.St. Paul Police Training Facility, 2621 Linwood Avenue East – Wetland Buffer Variance Agenda Item 4.a. 2 Sustainability Coordinator Finwall presented the St. Paul Police Training Facility wetland buffer variance. Deb Brandwick, AIA, Principal – Senior Project Architect, Oertel Architects detailed the project. Ms. Brandwick stated that the use of the site is not expanding, but some of the existing facilities are being replaced and upgraded. There is no sanitary sewer accessible to the site at this time, so they are required to install a new septic system. Sergeant Lisa Kruse, St. Paul Police Department, coordinator of the training facility, stated that the Class 5 area is part of the long-range firing range. They would like to maintain the Class 5 because the area can get muddy. Additionally, people occasionally park on the surface and it is plowed in the winter on occasion. Marlys Howells, 566 Deer Ridge Lane, nearby neighbor to the property, expressed concern about the St. Paul Police Training Facility improvements. She stated that noise from the training facility has been a long-time issue. She recommends the City add conditions to the use to include limiting hours of operation from 9 a.m. to noon when children are in school and not to allow the use in the summer. The Environmental and Natural Resources Commission had the following comments and questions regarding the wetland buffer variance: • Is the impervious surface increasing? Ms. Brandwick stated that they are maintaining the same square footage of impervious surface on the site. • Is the St. Paul Police Department open to expanding the wetland buffer adjacent the Class 5 and wetland edge? Ms. Brandwick stated the St. Paul Police Department is willing to add native plants along the wetland adjacent the Class 5 surface but recommends the plants be short to ensure they don’t impact the firing range. • There should be signage or a fence along the native plants adjacent the Class 5 to ensure no one parks on the native plants or that snow is not stored in that area. • Additional native plants should also be planted on the north side of the eastern wetland where the area is mowed to the edge of the wetland. • The buckthorn removal should be concentrated in the wetland buffer, not within the internal site where grading is already taking place. • Additional information is needed to assess the wetland buffer mitigation including square footage of overall mitigation including area of buckthorn removal and native planting versus area of impact to the wetland buffers, and how the new native plants will be protected along the Class 5 surface with a fence or additional signage. Commissioner Pearce-Saunders moved to table the St. Paul Police Training Facility wetland buffer variance in order for the applicant to submit additional wetland buffer mitigation details for review during the May ENR Commission meeting. 3 Seconded by Commissioner Guell. Ayes – All The motion passed. 6. UNFINISHED BUSINESS 7. VISITOR PRESENTATIONS None 8. COMMISSIONER PRESENTATIONS None 9. STAFF PRESENTATIONS Sustainability Coordinator Finwall updated the Environmental and Natural Resources Commission on the following: a. Update on Rescheduling of Environmental and Natural Resources Commission Meetings to Second Wednesday of the Month. Staff is coordinating the rescheduling with communications and the new meeting dates may begin in June. b. Spring Clean Up – May 3, 8 a.m. to 1 p.m., Aldrich Arena c. Arbor Day Tree Planting Demonstration – May 3, 10 a.m., Edgerton Park . Waterfest – May 31, 11 a.m. to 4 p.m., Lake Phalen Park. Commissioners Wes Saunders-Pearce and Cryer offered to serve on the Waterfest Subcommittee. Staff will send an e-mail update to the Commission to determine if other Commissioners would like to assist with the Waterfest booth. e. Commission Calendar. Staff presented the following draft calendar for the Commission: • May 19: Friends of Maplewood Nature, Annual Report • June 16: Green Building Code/Possible Capital Region Watershed District Tour • July 21: Environmental Center Tour, 6 to 7:30 p.m. • August 18: Green Building Code/Possible Capital Region Watershed District Tour • September 15: BizRecycling/Energy Smart 10. ADJOURNMENT Chairperson Lates made a motion to adjourn the meeting. Seconded by Commissioner Cryer. Ayes – All The motion passed. Chairperson Lates adjourned the meeting at 8:32 p.m. ENVIRONMENTAL & NATURAL RESOURCES COMMISSION STAFF REPORT Meeting Date May 19, 2025 REPORT TO: Environmental and Natural Resources Commission REPORT FROM: Shann Finwall, AICP, Sustainability Coordinato PRESENTER: Shann Finwall, AICP, Sustainability Coordinato AGENDA ITEM: St. Paul Police Training Facility, 2621 Linwood Avenue East - Wetland Buffer Variance Action Requested:  Motion ☐Discussion ☐ Public Hearing Form of Action: Resolution ☐ Ordinance ☐ Contract/Agreement ☐ Proclamation Policy Issue: The City of St. Paul Police Department proposes to update the existing training facility at 2621 Linwood Avenue East. Ramsey County owns the property, and the City of Saint Paul has leased it since the mid-1960s. The proposed plans replace the classroom training facility and include accessibility and safety upgrades. To move forward with the proposal, the applicant requests approval of a conditional use permit, design plans, and a wetland buffer variance. Recommended Action: Motion to approve a wetland buffer variance resolution and wetland buffer mitigation strategies for the St. Paul Police Training Facility updates at 2621 Linwood Avenue East. Fiscal Impact: Is There a Fiscal Impact?  No ☐ Yes, the true or estimated cost is $ 0.00 Financing source(s): ☐ Adopted Budget ☐ Budget Modification ☐ New Revenue Source ☐Use of Reserves  Other: n/a Strategic Plan Relevance: ☐Community Inclusiveness ☐Financial & Asset Mgmt Environmental Stewardship ☐Integrated Communication  Operational Effectiveness ☐Targeted Redevelopment The City deemed the project application complete on March 27, 2025. The City extended the 60- day review timeline to July 25, 2025, as outlined in State Statute 15.99 to ensure adequate time to review the project. The Environmental and Natural Resources Commission reviews wetland buffer variances to rectify impacts by reviewing and making recommendations for possible repair, rehabilitation, or restoration of the wetland buffer. Agenda Item 5.a. Background: Project Overview The City of St. Paul Police Department proposes to update the existing training facility at 2621 Linwood Avenue East. Ramsey County owns the property, and the City of St. Paul has leased it since the mid-1960s. The proposed plans replace the classroom training facility with accessibility and safety upgrades, including a classroom, two armories, men's and women's locker rooms, a kitchenette/break room, and ADA-compliant restrooms. The existing facility utilizes well and septic infrastructure, both of which will be replaced due to the age of the existing systems. Additional details on the proposed training facility updates are found on the attached project background report. The report includes information on the City’s land use requirements including conditional use, design review, and wetland buffer permits as outlined in the April 15 Planning Commission and April 21 Environmental and Natural Resources Commission reports. Environmental and Natural Resources Commission Review The Environmental and Natural Resources Commission reviewed the wetland buffer variance and mitigation strategies on April 21, 2025, and recommended tabling the project until the May meeting in order to review additional wetland buffer impact mitigation strategies including: 1. Area of Wetland Buffer Impact: Identify the square footage of impacts to the 100-foot wetland buffers. 2. Area of Wetland Buffer Mitigation: Identify the square footage of proposed wetland buffer mitigation strategies to equal 2 square feet of mitigation versus 1 square foot of impact. 3. New Wetland Buffer: Addition of a new 10-foot wide wetland buffer with native plugs/seeds along the west and north side of the eastern wetland. 4. New Fence: Addition of a fence along the east side of the Class 5 and west side of the newly established 10-foot wide wetland buffer. 5. Wetland Buffer Signs: In addition to the required wetland buffer signs, the applicant should install additional signage along the newly established 10-foot wide wetland buffer adjacent the Class 5 surface to ensure no parking or snow plow storage within the buffer. 6. Buckthorn Removal: Buckthorn removal concentrated in the wetland buffer, not within the internal site where grading is already taking place. Revised Wetland Buffer Mitigation Plan The applicants submitted revised plans dated May 5, 2025, that address most of the Environmental and Natural Resource Commission’s April recommendations as follows: 1. Wetland Buffer Impacts: The square footage of impacts within the 100-foot buffer were not included on the plans. 2. Wetland Buffer Mitigation: The square footage and wetland buffer mitigation strategies are identified on the removal and restoration plan. The applicants are proposing a total of .15 acres of wetland buffer mitigation as follows - Zone 1A:  .06 acres located on the north side of the eastern wetland.  Remove and treat all buckthorn, honeysuckle, and Japanese knotweed. Zone 1B:  .02 acres located on the south side of the eastern wetland.  Remove and treat all buckthorn, honeysuckle, and Japanese knotweed. Zone 2:  .05 acres located on the east side of the eastern wetland adjacent the Class 5.  Remove and treat all Japanese knotweed and reed canary grass.  Seed with wetland edge seed mix.  Plant wetland edge native plugs, 24 inches on center. Zone 3:  .02 acres of Class 5 being removed along the eastern wetland.  Remove four dead ash trees.  Remove gravel and replace with topsoil.  Seed with mesic prairie seed mix.  Plant Mesic native plugs, 24 inches on center throughout. 2. New Fence: The fence will be constructed of galvanized posts with chains. The height of the fence is unspecified. The fence will be constructed on the east side of the Class 5 and west side of the newly established buffer. 3. Wetland Buffer Signs: The site plan shows wetland buffer signs placed at 100’ intervals around the wetland with additional signage placed on the fence at approximately 25’ intervals. 4. Buckthorn Removal: Buckthorn removal is concentrated within the wetland buffer as recommended by the Environmental and Natural Resources Commission in the areas detailed in item 2 above. Commission and City Council Review Community Design Review Board April 15, 2025: The Community Design Review Board recommended approval of the building design plans with no changes. Planning Commission April 15, 2025: The Planning Commission held a public hearing and then recommended approval of the conditional use permit and wetland buffer variance. Environmental and Natural Resources Commission April 21, 2025: The Environmental and Natural Resources Commission tabled the wetland buffer variance and requested additional wetland buffer mitigation strategies. May 19, 2025: The Environmental and Natural Resources Commission will review the wetland buffer variance and amended wetland buffer mitigation strategies and make a recommendation to the City Council. City Council June 9, 2025: The City Council is scheduled to review the conditional use permit, design plans, and wetland buffer variance requests. Attachments: 1. Project Background 2. Overview Map 3. Zoning Map 4. Wetland Overlay Map 5. St. Paul Police Training Site Variance Request Memo Outlining Wetland Buffer Mitigation Strategies 6. May 5, 2025, Updated Plans 7. Engineering Review Dated April 2, 2025 8. Environmental Review Dated April 2, 2025 9. Wetland Buffer Variance Resolution Project Background Saint Paul Police Training Facility 2621 Linwood Avenue Shann Finwall, AICP, Sustainability Coordinator Elizabeth Hammond, Planner May 15, 2025 Project Background Overview The City of Saint Paul Police Department proposes to update the existing training facility at 2621 Linwood Avenue East. Ramsey County owns the property, and the City of Saint Paul has leased it since the mid-1960s. The proposed plans replace the classroom training facility with accessibility and safety upgrades, including a classroom, two armories, men's and women's locker rooms, a kitchenette/break room, and ADA-compliant restrooms. The existing facility utilizes well and septic infrastructure, both of which will be replaced due to the age of the existing systems. Conditional Use Permit Maplewood city code requires a conditional use permit (CUP) for the public building and its use on the property. When the Saint Paul Police Department began leasing the site from Ramsey County, a CUP was never obtained. The site's use is not changing, and the number of individuals from the Saint Paul Police Department who intend to utilize it is not anticipated to increase largely. To proceed, the proposed project requires the property to obtain a CUP to comply with the city code. Site Plan The 3,196-square-foot training facility is proposed in the southwest section of the site, adjacent to the existing building (which will be demolished). The site is accessed from the existing entrance point off Linwood Avenue. A small parking area is provided on the north and east sides of the proposed building. Septic and Well There is currently no sewer and water available at the site. The existing facility utilizes well and septic infrastructure, which will be replaced as part of this project. There is residential development proposed on the northeast corner of the county site (old Ponds of Century Golf Course). That development would require the extension of sewer and water in the area. However, the applicant has indicated the timing of that sewer and water extension does not align with their priority to complete this project as soon as possible. Setbacks The building and parking areas are set back 201 feet from the property line to the south along Linwood Avenue and 84 feet to the property line to the west. The building and parking areas are screened from the adjacent public streets and residential properties. City code requires the building to be 30 feet from a street right-of-way and 50 feet from a residential lot line, and 1 Attachment 1 parking areas to be 15 feet from a street right-of-way and up to 20 feet adjacent to residential property. All setbacks are achieved. Building Elevations The one-story building varies in height between 12.6 feet and 19.2 feet as the grade changes. The proposed materials are insulated CMU blocks in a black and gray tone and asphalt shingles in a charcoal color. The building is not visible from the adjacent public streets or residential properties. Signage Any signage on the property is subject to review by the city and requires a sign permit, separate from this design review. Trees The proposed landscape plan shows 18 trees would be removed and 18 new trees planted. All other tree coverage on the site remains to provide visual and acoustic screening of the building and exterior training areas. Parking City code does not identify a parking requirement for this proposed use; however, the code allows the community development director to review the parking requirements for a use similar to determining the space requirements. The applicant proposes 14 parking stalls, including one accessible stall. As a comparison, the City Code requires one parking stall for every 200 square feet of floor area for commercial, office, or recreational building use. Based on this type of use, the site would be required to have 16 parking stalls. The site will continue to be utilized privately by the City of Saint Paul Police Department for training. The site is not meant for regular public use, so staff believes the number of stalls is adequate. Lighting The applicant submitted a lighting plan illustrating the location and lighting types, which includes wall-mounted lighting on site. Also, a plan showing the light spread and foot-candle levels was provided, showing the levels at the [property lines meet code requirements. Wetlands There are two Manage A wetlands affecting the development, one adjacent the property on the vacant lot to the west and one on the east side of the property. The City’s wetland ordinance requires a 75-foot minimum and 100-foot average wetland buffer around a Manage A wetland. Any deviation from the wetland buffer requires a wetland buffer variance. Before the City Council acts on a wetland buffer variance the Environmental and Natural Resources Commission makes a recommendation on the variance and mitigation plans. A wetland buffer mitigation plan is required to include one or more of the following strategies: 1. Reducing or avoiding the impact by limiting the degree or amount of the action, such as by using appropriate technology. 2 2.Rectifying the impact by repairing, rehabilitating, or restoring the buffer. 3.Reducing or eliminating the impact over time by prevention and maintenance operations during the life of the actions. 4.Compensating for the impact by replacing, enhancing, or providing substitute buffer land at a two-to-one ratio. 5.Monitoring the impact and taking appropriate corrective measures. 6.Where the City requires restoration or replacement of a buffer, the owner or contractor shall replant the buffer with native vegetation. A restoration plan must be approved by the City before planting. 7.Any additional conditions required by the applicable watershed district and/or the soil and water conservation district shall apply. 8.A wetland or buffer mitigation surety, such as a cash deposit or letter of credit, of 150 percent of estimated cost for mitigation. The surety will be required based on the size of the project as deemed necessary by the administrator. Funds will be held by the city until successful completion of restoration as determined by the city after a final inspection. Wetland or buffer mitigation surety does not include other sureties required pursuant to any other provision of city ordinance or City directive. Wetland Buffer Impacts The site was originally developed and graded prior to the City’s wetland ordinance and wetland buffer requirements. The existing drive lane, tactical training buildings, storage building, and gravel pad extend into the 100-foot wetland buffers and are considered pre-existing nonconforming structures and encroachments. Any expansion of those uses require compliance with the current wetland buffer requirements. The expanded training facility will have grading to within approximately 53 feet of the eastern Manage A wetland for the extension of a utility line, parking stall, and grading to within 59 feet of the westerly Manage A wetland for building earthwork. Other portions of the new development will be located within the 75-foot minimum buffer. With the wetland buffer impacts, the development requires a 41-foot wetland buffer variance, wetland buffer averaging, and wetland buffer mitigation as required by the wetland ordinance. To approve a variance, the City Council shall apply the findings for variance approval as required in Minnesota Statutes. Those findings require that the applicant show practical difficulties in complying with the official controls. The applicant’s variance justification narrative attached outlines practical difficulties in developing the site including the pre-existing nonconforming conditions, the narrow area for development due to the location of two wetlands, and the need for a new septic system which requires setbacks to the well and the natural undisturbed soils requiring encroachments into the wetland buffer. Department Comments Fire – Jerry Novak, Fire Marshal A sprinkler system will be required for the proposed building. 3 Building – Randy Johnson, Building Official The proposed building will need to be constructed to meet the minimum requirements of the Minnesota State Building Code. Environmental – Shann Finwall, Sustainability Coordinator Please see the environmental review dated April 2, 2025. Engineering – Jon Jarosch, Assistant City Engineer Please see the engineering review dated April 2, 2025. Public Comments Staff sent a public hearing notice and application details to the properties within 500 feet of the subject property. No public comments were received prior to the public hearing. Reference Information Site Description Site Size: 37.06 Acres Surrounding Land Uses North: Residential Park Land South: Residential Dwellings East: Residential Dwellings in the City of Woodbury West: Residential Dwellings Planning Existing Land Use: Park Existing Zoning: Farm Residential 4        !""#$%&'()*+,-.%/0123)4%%567189).+%&:-. Attachment 2       !"#$"!! %&'()!*"+,-#"."!/01"-%02+( Attachment 3           !"!#$% !"!#$& !"!#$' Attachment 4 1 1795 St. Clair Avenue | St. Paul, MN 55105 | (651) 696-5186 www.oertelarchitects.com An Affirmative Action, Equal Opportunity Employer Subject Date May 12, 2025 To: Elizabeth Hammond Shann Finwall From: Deb Brandwick RE: 2621 Linwood, Wetland Setback Variance Request Elizabeth and Shann, The project in question is the St. Paul Police Training Facility at 2621 Linwood Avenue. The existing site includes a classroom building that is proposed to be demo’d, a storage building proposed to remain, two shooting range areas to remain, and an area developed with partial structures for tactical training. The site has been utilized as a firing range since approximately 1975 (see included lease agreement). The failure of the existing septic system, disrepair and non-accessibility of the classroom building, and undrinkable well water have created the need for this proposed project. The site appears to have been graded in the 1975 era to provide a relatively flat area for the firing ranges, support buildings and parking. The surrounding bowl was kept intact, if not enhanced, to provide visual and sound protection for the firing ranges. While the bulk of existing development is between the two setbacks, the drivelane, tactical training buildings, storage building and gravel pad extend into the buffer setbacks. Both wetlands are listed as Manage A type, requiring a 100’ buffer/setback area to all improvements. With the two setbacks and the grading of the bowl, the developable portion of the site is extremely limited. Our proposed project will locate a new building between the two buffer setbacks. 11 of the required parking stalls are between the buffers, with three stalls between the 75’ and 100’ buffer lines. The area of the encroaching parking stalls is on an existing paved area, with the project including improvement of the pavement to provide a slight regrading to allow for proper drainage of the area. An area to the NE of the construction extents crosses the 75’ buffer line to allow for connection of the electrical utility. The area of disruption will be limited to that needed for electrical line only. This area is within an existing improved hard surface (class V). The new/replacement septic field is located to the SE of the construction limits, crossing the 100’ and 75’ buffer lines. A memo from the septic designer is attached describing the limited options for location of the septic field. The pipe between the septic tanks and the field will run between the 100’ and 75’ buffer lines. The area west of the proposed new building requires some regrading to allow for building access, accessible parking and to maintain access to the existing storage building. The amount of grading has been minimized by utilizing the building wall as a partial retaining wall, but the grading does extend across the 75’ buffer line, but the majority of the area to be regraded is already improved hard surface area. Attachment 5 2 1795 St. Clair Avenue | St. Paul, MN 55105 | (651) 696-5186 www.oertelarchitects.com An Affirmative Action, Equal Opportunity Employer Variance Request: We request the proposed project be approved to encroach into the wetland buffer as shown on the attached site plans. The dimensions of encroachment vary and are dimensioned on the site plan, and summarized here: Encroachment of grading at west edge of building earthwork: 12’ to 16’ Encroachment of septic field: 13’ Enchroachment of electrical utility: 21.5’ Encroachment of regrading at existing driveway: 11.5’ to 29.5’ Variance Reasoning: A.1 Reasonableness: The City of St. Paul intends to continue the use of property as a police training and firing range, as it has since 1975. The existing classroom building is in disrepair and not accessible, the septic system has failed requiring the use of porta-potties on site, and the well water is currently not drinkable. Thus, to maintain the existing use of the property, a new building and new utilities are required. The building, well and septic tanks will be outside of the buffer areas, but due to the tightness of the site, some grading to maintain access to existing features and create an accessible new building will encroach on the buffers. Please see attached memo for details relating to the location of the proposed septic field. The number of trainees utilizing the site is not proposed to change from counts prior to the septic system failure. A.2. Uniqueness: The property is largely covered by the main wetland and a steep sloping bowl at the perimeter. This leaves little flat developable land without encroaching into the sloped grades of the buffer areas. The workable area between the buffers is fully utilized by the building(s), parking, shooting ranges and tactical training area. The sloped areas are important to maintain on this site to buffer the neighboring lots from the visuals and sounds of the firing range. Thus, the proposed project is utilizing the lower bowl to the extent possible. Due to previous construction, a large class V pad exists just west of the main wetland. The project proposes improving a portion of that pad for better site drainage. The lack of City sewer and water creates the need for the septic field and well. Due to regulations around each of those independent of the wetland regulations, locating outside of the buffer would require displacing required parking, or regrading a steeper sloped portion of the site and removal of an additional number of trees. A.3 Essential Character: Due to the nature of the site grading, 308 inventoried trees, and the proposed new structure at the bottom of the bowl, the development will not be visible to adjacent properties, or from Linwood Avenue. 3 1795 St. Clair Avenue | St. Paul, MN 55105 | (651) 696-5186 www.oertelarchitects.com An Affirmative Action, Equal Opportunity Employer B. A portion of the buffer encroachment is in locations where hardscape improvements have previously been made. Thus, the current proposed improvements do not diminish the intent of the buffer ordinance. The unimproved buffer areas where encroachment is proposed have been minimized by utilizing the building as retaining wall, minimizing extents of construction to actual utility locations and needs. By minimizing tree removing, providing the required tree replacements, removing buckthorn from sections of the buffer, and application of native seeding to improve the buffer areas, the project is intending to meet the requirements to protect and maintain wetland areas, while maintaining the existing historical use of the site. Per the April ENR meeting, we are showing a 10’ enhanced buffer at the perimeter of the east wetland. Buckthorn, honeysuckle and Japanese knotweed will be removed from this area with a three year agreement form the City of St. Paul to maintain the elimination those plants. Note that at the east side of the wetland, we are not noting those removals, as none currently exist, and no additional work is proposed for the far east side of the site. East side of wetland, looking SW 4 1795 St. Clair Avenue | St. Paul, MN 55105 | (651) 696-5186 www.oertelarchitects.com An Affirmative Action, Equal Opportunity Employer In addition, a fence is proposed at the west edge of the 10’ buffer to prevent any incidental traffic or snowplowing activities in that area. The fence as proposed is galvanized posts with two chains between posts. Required wetland signage will be placed at 100’ intervals around the wetland with additional signage placed on the fence at approximately 25’ intervals. West side of wetland, looking north Attachment: Wetland Buffer Variance_Septic Variance Site Plan Variance Jus fica on of the New SSTS at the St. Paul Gun Range Author: Jesse Kloeppner – Advanced Designer Kloeppner Services & Design, LLC Here is a summary of the jus fica on of the placement of the SSTS. The system will infringe on the wetland buffer of 100 feet. Reasonable – The new SSTS system for the St Paul Gun Range will require three new precast tanks and a soil treatment area large enough for the es mated daily flow of the staff and guests. The loca on of the precast tanks will not infringe or encroach into the 100-foot buffer from the two delineated wetlands for the St Paul Gun Range site. However, the newly designed soil treatment area (mound) will be within 100 feet of the wetland along the Eastern of edge of the site. The loca on of the new mound was iden fied based on the need to iden fy natural, undisturbed soil, as well as an area large enough for the mound. Please note, the system cannot be placed in the same loca on as the original noncompliant trenches. So, a new area must be iden fied where the soil has not been cut, filled, or disturbed. Due to the buffers for the two wetlands, the amount of disturbed soil for the driveway, constructed berms around the building and range, necessary setback from the well, and the need for natural soil, the area on the top of the hill along Linwood Avenue is the best place for a soil treatment area. Uniqueness - The placement of the new mound is located along the hillside with a slope that is less than 12% and does not require a lot of trees to be removed . The construc on of a mound on slope >12% becomes a challenge to maintain the constructability and overall size. The longer and wider mound will require greater amounts of soil to build and need to remove addi onal trees. Due to the cut and disturbed soil throughout the site, this loca on provides the only viable long-term solu on. Though it looks as though the system could easily be moved to the West to meet the 100-foot buffer requirement, the topography does not allow the mound to be built according to standards set by the defini ons for mound construc on by MPCA rules in Chapter 7080. The mound must be placed along the same contour and cannot be cut or graded to establish the upslope contour. Essen al character – The value of the loca on of the new mound serves as a great place to build a 4.5-foot-tall mound that will be 52.9’ wide by 83.4’ long. Though the mound will be visible from Linwood Ave, once the grass is established, it will be part of the natural hill landscape and provides an addi onal barrier from the ac vi es of the Gun Range and neighbors. Attachment 6 1795 Saint Clair Avenue phone: (651) 696-5186 St. Paul, Minnesota 55105 www.oertelarchitects.com SHEET NO: SHEET NAME: I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: REVISIONS: PR O J E C T N A M E : Not for Cons t r u c t i o n NOTES: CLIENT: CONSULTANT: LICENSE #DATE DRAWN BY CHECKED BY PROJECT NUMBER DATE © 2020 COPYRIGHT PIERCE PINI & ASSOCIATES ALL RIGHTS RESERVED. RSPRJD 05/12/202524-021 OERTEL ARCHITECTS, LTD. ST P A U L P O L I C E TR A I N I N G F A C I L I T Y 26 2 1 L i n w o o d A v e E , M a p l e w o o d , MN 5 5 1 1 9 PIERCE PINI & ASSOCIATES ENR COMMITTEE RESUBMITTAL C400 GRADING AND DRAINAGE PLAN 1795 Saint Clair Avenue phone: (651) 696-5186 St. Paul, Minnesota 55105 www.oertelarchitects.com SHEET NO: SHEET NAME: I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: REVISIONS: PR O J E C T N A M E : Not for Cons t r u c t i o n NOTES: CLIENT: CONSULTANT: LICENSE #DATE DRAWN BY CHECKED BY PROJECT NUMBER DATE © 2020 COPYRIGHT PIERCE PINI & ASSOCIATES ALL RIGHTS RESERVED. RSPRJD 05/12/202524-021 OERTEL ARCHITECTS, LTD. ST P A U L P O L I C E TR A I N I N G F A C I L I T Y 26 2 1 L i n w o o d A v e E , M a p l e w o o d , MN 5 5 1 1 9 PIERCE PINI & ASSOCIATES ENR COMMITTEE RESUBMITTAL C600 SITE LAYOUT & PAVING PLAN ZONE 1B: APPROX. 0.2 ACRES ZONE 2: APPROX. 0.05 ACRE ZONE 3: APPROX. 0.02 ACRE ZONE 1A: APPROX. 0.06 ACRES twenty 0' 10' 20' 40' L1.0 n 2 3 1 1 1 OERTEL ARCHITECTS, LTD. 1795 Saint Clair Avenue phone: (651) 696-5186 St. Paul, Minnesota 55105 www.oertelarchitects.com SHEET NO: SHEET NAME: REMOVALS & VEGETATIVE RESTORATION PLAN PLOTTED:PROJECT NAME: I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: REVISIONS: PR O J E C T N A M E : Not for Cons t r u c t i o n NOTES: CLIENT: CONSULTANT: LICENSE #DATE DRAWN BY CHECKED BY PROJECT NUMBER DATE © 2020 COPYRIGHT OERTEL ARCHITECTS. ALL RIGHTS RESERVED. Not for Construction Not for Construction Not for Construction Not for Construction 5/2/2025 1:02:03 PM 23-28C ST PAUL POLICE TRAINING FACILITY ST P A U L P O L I C E TR A I N I N G F A C I L I T Y 26 2 1 L i n w o o d A v e E , M a p l e w o o d , MN 5 5 1 1 9 COMMUNITY DESIGN REVIEW No. Date Description REMOVALS & RESTORATION PLAN • WINTER 2025: INITIAL BUCKTHORN CUTTING, STUMP TREATMENT, AND STAGING OF CUT MATERIAL. • SUMMER, 2025: MECHANICAL FOLLOW UP CUTTING OF ALL BUCKTHORN REGROWTH AND ANY MISSED BUCKTHORN AS NEEDED DEPENDING ON CONDITIONS. • FALL, 2025: FOLIAR HERBICIDE APPLICATION FOLLOW UP OF ALL BUCKTHORN REGROWTH. • FALL, 2026: FOLIAR HERBICIDE APPLICATION FOLLOW UP OF ALL BUCKTHORN REGROWTH. • FALL, 2027: FOLIAR HERBICIDE APPLICATION FOLLOW UP OF ALL BUCKTHORN REGROWTH. ANTICIPATED BUCKTHORN REMOVAL SCHEDULE: (SCHEDULE IS TBD THE FOLLOWING IS AN EXAMPLE SCHEDULE TO BE IMPLEMENTED) SCOPE THE WORK IN THIS SECTION CONSISTS OF FURNISHING ALL LABOR, MATERIALS, EQUIPMENT, ACCESSORIES, AND PERFORMING ALL OPERATIONS REQUIRED, WHICH GENERALLY INCLUDES THE FOLLOWING WORK: · PROVIDE FINE GRADING AND SOIL PREPARATION, REMOVING EXTRANEOUS MATTER MOSTLY INCLUDING REED CANARY GRASS IN THE POND BUFFER AREA, AND GRADING TO A SMOOTH GRADE. PROVIDE NATIVE SEEDING/PLANTINGS IN AREAS DESIGNATED ON DRAWINGS. · INSTALLATION OF TEMPORARY STABILIZATION MEASURES. · MAINTENANCE, ESTABLISHMENT AND GUARANTEE OF ALL PLANTED/SEEDED AREAS. REMOVAL OF WOODY INVASIVE PLANTS, QUALIFICATIONS INSTALLER'S QUALIFICATIONS: REMOVALS, APPLICATIONS, FINAL PREPARATION OF GRADING AND PLANTING/SEEDING WORK SHALL BE PERFORMED BY A SINGLE FIRM. TO QUALIFY, THE CONTRACTOR MUST PROVIDE THE FOLLOWING DOCUMENTATION TO THE PROJECT MANAGER UPON REQUEST: · THE FIRM HAS A MINIMUM FIVE YEARS' EXPERIENCE IN FINE GRADING, PLANTING/SEEDING AND ESTABLISHMENT OF NATIVE PLANT MATERIAL OF A PROJECT SIMILAR OR GREATER IN SIZE TO THIS PROJECT. · THE CONTRACTOR SPECIALIZES IN NATIVE PRAIRIE AND/OR WETLAND INSTALLATIONS AND RESTORATION. · SUBMIT POST INSTALLATION IMAGES OF SUCCESSFUL INSTALLATIONS WITHIN THE LAST 5 YEARS, INDICATING SEEDING/PLANTING RATES, LOCATION OF PROJECT, DATES OF INSTALLATION AND DATES PHOTOGRAPHS WERE TAKEN. A MINIMUM OF 5 PROJECTS WITH AT LEAST TWO (2) PHOTOS OF EACH INSTALLATION MUST BE SUBMITTED. · ASSIGNMENT OF A QUALIFIED PROJECT SUPERVISOR CAPABLE OF BEING PRESENT FULL-TIME DURING ALL INSTALLATION AND MAINTENANCE WORK. QUALIFICATIONS WILL INCLUDE: A. A BACHELOR'S DEGREE IN NATURAL RESOURCES MANAGEMENT OR RELATED FIELD. B. MINIMUM OF FIVE YEARS' EXPERIENCE IN LANDSCAPE RESTORATION AND MAINTENANCE SUPERVISION, WITH EXPERIENCE OR TRAINING IN PRAIRIE AND WETLAND MANAGEMENT, ENTOMOLOGY, PEST CONTROL, SOILS, FERTILIZERS AND PLANT IDENTIFICATION. C. CURRENT HERBICIDE AND PESTICIDE APPLICATORS LICENSE WOODY INVASIVE SPECIES REMOVAL A. TARGET WOODY SPECIES TO BE REMOVED INCLUDE COMMON BUCKTHORN (RHAMNUS CATHARTICA) AND GLOSSY BUCKTHORN (FRANGULA ALNUS), HONEYSUCKLE (MORROW'S, TATARIAN, BELL'S OR AMUR)JAPANESE KNOTWEED (POLYGONUM CUSPIDATUM). B. WINTER CUT AND STUMP TREAT INITIAL REMOVAL OF TARGET SPECIES – I. ALL MATERIAL FROM TARGET SPECIES MUST BE CUT STUMP TREATED UNLESS TOO SMALL (< 1” DBH) TO TREAT EFFECTIVELY. MATERIAL <1” DBH WILL NEED TO BE FOLLOWED UP WITH FOLIAR SPRAY OR BASAL BARK WHEN CONDITIONS ARE SUITABLE. II. CUT STUMP TREATMENT SHOULD BE CONDUCTED IN WINTER UNLESS CHEMICAL IS WATER BASED AND CONDITIONS ARE NOT RIGHT. III. STUMPS MUST BE CUT TO WITHIN 3” OF GRADE OR EXISTING SNOW COVER. STUMPS MUST BE CUT FLAT, NOT SHREDDED OR LEFT WITH AN ANGLED TOP. IV. TRICLOPYR ESTER (GARLON 4 ULTRA OR APPROVED EQUIVALENT) IS PREFERRED FOR ALL WINTER AND EARLY SPRING CUT STUMP TREATMENTS UNLESS OTHERWISE STATED. AN OIL-BASED CARRIER PRODUCT (E.G. DILUENT BLUE™) SPECIFICALLY DESIGNED FOR HERBICIDE USE MUST BE USED. THE USE OF DIESEL FUEL OR OTHER UNAPPROVED PRODUCTS AS A CARRIER IS NOT ALLOWED. V. HERBICIDE MUST BE SPOT APPLIED TO CUT STUMPS WITH A BACKPACK SPRAYER OR HANDHELD SPRAYER. VI. CARE MUST BE TAKEN TO APPLY HERBICIDE TO THE ENTIRE OUTER RING (CAMBIUM AREA) OF THE STUMP SURFACE, AND TO AVOID NON-TARGET DAMAGE. VII. FOR CUT STUMP OR BASAL STEM TREATMENT IN WETLAND OR NEAR AQUATIC AREAS, ONLY AQUATIC-RATED HERBICIDES CONTAINING ACTIVE INGREDIENT TRICLOPYR ARE APPROVED. VIII. CUT STUMPS MUST BE TREATED WITHIN 2 HOURS OF CUTTING, IDEALLY TREATED WITHIN MINUTES AFTER CUTTING. IX. IN AREAS OF HIGH DENSITY OR WITH CUT MATERIAL >1” DBH, CUT MATERIAL MUST BE STAGED IN WILDLIFE HABITAT PILES IF DISPERSAL OF THE MATERIAL WITHIN THE UNIT WOULD EXCEED A SINGLE LAYER OF MATERIAL OR IMPEDE FUTURE UNIT ACCESS. X. PILES MUST BE NO LARGER THAN 15 FEET SQUARE BY 6 FEET TALL AND SHOULD BE SPACED EVENLY THROUGHOUT THE APPLICABLE AREAS OF THE UNIT. C. GROWING SEASON CRITICAL CUT – I. CRITICAL CUT IS TO HAPPEN IN LATE JULY – MID AUGUST 2025 FOCUSING ON TARGET SPECIES IF REGROWTH IS SIGNIFICANT ENOUGH TO REQUIRE THIS ACTION FOR CONTINUED REMOVAL MAINTENANCE. II. IF THIS WORK HAS BEEN BUDGETED FOR 2025 BUT REGROWTH DOESN’T REQUIRE THIS ACTION, FUNDS WILL BE REALLOCATED TO SUPPORT OTHER ACTIONS REQUIRED AT THE FUTURE TIME. III . CUT AND SLASHED MATERIAL WILL NEED TO BE BUCKED UP AND DISPOSED OF. D. WOODY INVASIVE SPECIES FOLIAR FOLLOW-UP APPLICATION I. APPLY FOLIAR SPRAY BEFORE FIRST FALL FROST AND BEFORE COMMON BUCKTHORN SENESCENCE. WHIPS >3’ TALL MUST BE CUT FIRST AND RE-GROWTH SPRAYED. FOR OTHER SPECIES, APPLY FOLIAR SPRAY IN LATE FALL BEFORE LEAVES SENESCE, DURING SAP WITHDRAWAL. II. FOLIAR TREATMENT SHOULD BE CONDUCTED IN LATE SUMMER/EARLY FALL III. TRICLOPYR FORMULATIONS (E.G. GARLON 3A) ARE PREFERRED FOR SUMMER FOLIAR APPLICATIONS TO LIMIT THE POTENTIAL FOR VOLATILIZATION AND OFF TARGET IMPACT OF THE CHEMICAL. IV. MATERIAL UNDER 1” DBH THAT IS UNABLE TO BE STUMP CUT WILL NEED FOLLOW UP FOLIAR SPRAY DURING SUITABLE CONDITIONS. KILL RATE FOR FOLIAR APPLICATION IS ≥95%. V. SPRAY OPERATORS SHOULD TAKE CARE TO SPRAY (CHOOSE ALL OR >50% OF) LEAF SURFACES OF TARGETED SPECIES AND AVOID SPRAYING ON THE TOP LAYER OF LEAVES. VI. NO FOLIAR HERBICIDE APPLICATIONS USING AN ESTER FORMULATION (E.G. GARLON 4) SHALL BE MADE DURING THE MONTHS OF JUNE, JULY, OR AUGUST. VII. NO FOLIAR HERBICIDE APPLICATIONS (REGARDLESS OF FORMULATION) SHALL BE PERFORMED WHEN THE DAILY TEMPERATURE IS PREDICTED TO BE >85 DEGREES F WITH A CORRESPONDING RELATIVE HUMIDITY OF <45% AT ANY TIME DURING THE DAY (NOT JUST AT THE TIME OF APPLICATION). VIII. SUBCONTRACTOR WILL ALLOW A MINIMUM OF TWO WEEKS BETWEEN APPLICATIONS TO FOR THE TREATMENT TO TAKE FULL EFFECT. E. GENERAL HERBICIDE APPLICATION SPECIFICATIONS I. HERBICIDE APPLICATIONS WILL FOLLOW THE APPROPRIATE HERBICIDE LABEL DIRECTIONS. II. THE ACTIVE INGREDIENT MUST BE OF SUFFICIENT PERCENTAGE TO BE EFFECTIVE. III. ALL HERBICIDE TREATMENTS MUST CONTAIN A MARKER DYE SUFFICIENT TO SHOW EXTENT OF STUMPS AND STEMS TREATED. THE COLOR OF THE MIXED PRODUCTS ALONE IS INSUFFICIENT. IV. HERBICIDE MUST BE APPLIED UNDER DRY AMBIENT AND DRY STUMP CONDITIONS THAT WILL PERSIST FOR AT LEAST 24 HOURS FROM TIME OF APPLICATION. V. HERBICIDE MUST BE SPOT APPLIED WITH BACKPACK SPRAYER OR HANDHELD APPLICATION DEVICE. BOOM OR SIMILAR SPRAYERS ARE EXPRESSLY PROHIBITED. VI. (SUB)CONTRACTOR WILL ALLOW A MINIMUM OF TWO WEEKS BETWEEN APPLICATIONS FOR THE TREATMENT TO TAKE FULL EFFECT. VII. ALTERNATIVE HERBICIDES AND METHODS MAY BE CONSIDERED, BUT THEY MUST BE APPROVED IN WRITING BY THE PROJECT MANAGER PRIOR TO USE AND MUST BE ON THE DNR’S APPROVED LIST. CONTRACTOR MUST INITIATE THE APPROVAL REQUEST AND ALLOW 72-HOUR PRIOR NOTIFICATION FOR APPROVAL PROCESS. VIII. TRICLOPYR IX. IDEAL HERBICIDE APPLICATION TIMING: BASAL BARK APPLICATION IN WINTER, FOLIAR TREATMENT IN LATE SUMMER/EARLY FALL, CUT STUMP TREATMENT IN WINTER UNLESS CHEMICAL IS WATER BASED AND CONDITIONS ARE NOT RIGHT. X. TRICLOPYR ESTER (GARLON 4 ULTRA OR APPROVED EQUIVALENT) IS PREFERRED FOR ALL WINTER, EARLY SPRING, AND LATE FALL APPLICATIONS (CUT STUMP, BASAL STEM OR FOLIAR TREATMENT), UNLESS OTHERWISE STATED. XI. AN OIL-BASED, CARRIER MUST BE A PRODUCT SPECIFICALLY DESIGNED FOR HERBICIDE USE (E.G. DILUENT BLUE™); USE OF DIESEL FUEL AS A CARRIER IS NOT ALLOWED. XII. AMINE FORMULATIONS (E.G. GARLON 3A) ARE PREFERRED FOR SUMMER APPLICATIONS (JUNE, JULY, AUGUST) TO LIMIT THE POTENTIAL FOR VOLATILIZATION AND OFF TARGET IMPACT OF THE CHEMICAL. XIII. FOR CUT STUMP OR BASAL STEM TREATMENT IN WETLAND OR NEAR AQUATIC AREAS, ONLY AQUATIC-RATED HERBICIDES CONTAINING ACTIVE INGREDIENT TRICLOPYR ARE APPROVED. XIV. LABEL DIRECTIONS MUST BE FOLLOWED. ACTIVE INGREDIENT MUST BE OF SUFFICIENT PERCENTAGE TO BE EFFECTIVE. XV. BLUE DYE MUST BE ADDED TO HERBICIDE MIX (THIS IS IN ADDITION TO ANY BLUE COLORING INCLUDED IN DILUENT BLUE OR OTHER INGREDIENT). XVI. HERBICIDE MUST BE SPOT APPLIED TO STUMPS OR BASAL STEMS WITH BACKPACK SPRAYER OR HANDHELD SPRAYER. BOOM OR SIMILAR SPRAYERS ARE EXPRESSLY PROHIBITED. XVII. FOLIAR APPLICATION TO COVER >50% OF LEAF SURFACE AREA OF EACH INDIVIDUAL PLANT. CARE AT MINIMIZING OVERSPRAY MUST BE USED DURING ALL HERBICIDE APPLICATIONS (STUMP TREATMENT AND FOLIAR TREATMENT). XVIII. ORIGINAL HERBICIDE AND CARRIER CONTAINERS COMPLETE WITH LABELS MUST BE ON-SITE OR IN PARKING LOT, AND AVAILABLE FOR INSPECTION AT ALL TIMES. XIX. CUT STUMPS MUST BE TREATED WITHIN TWO (2) HOURS OF CUTTING. XX. HERBICIDE MUST BE APPLIED UNDER DRY AMBIENT AND DRY STUMP CONDITIONS THAT WILL PERSIST FOR AT LEAST 24 HOURS FROM TIME OF APPLICATION. XXI. SPILL KIT(S) MUST BE ON SITE AT ALL TIMES. XXII, NO FOLIAR HERBICIDE APPLICATIONS USING AN ESTER FORMULATION (E.G. GARLON 4) SHALL BE MADE DURING THE MONTHS OF JUNE, JULY, OR AUGUST. XXIII. NO FOLIAR HERBICIDE APPLICATIONS (REGARDLESS OF FORMULATION) SHALL BE PERFORMED WHEN THE DAILY TEMPERATURE IS PREDICTED TO BE ≥85⁰ F WITH A CORRESPONDING RELATIVE HUMIDITY OF ≤45% AT ANY TIME DURING THE DAY (NOT JUST AT THE TIME OF APPLICATION). XXIV. DAILY HERBICIDE LOGS MUST BE KEPT AND PROVIDED WEEKLY. REED CANARY GRASS REMOVAL A. PESTICIDES I. MUST COMPLY WITH CITY ORDINANCES II. PREFERRED PRODUCT IS GLYPHOSATE AND MUST BE REGISTERED AND APPROVED BY THE EPA, ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND OF TYPE RECOMMENDED BY MANUFACTURER FOR EACH SPECIFIC PROBLEM AND AS REQUIRED FOR PROJECT CONDITIONS AND APPLICATION. III. PRE-EMERGENT HERBICIDE (SELECTIVE AND NONSELECTIVE): EFFECTIVE FOR CONTROLLING THE GERMINATION OR GROWTH OF WEEDS WITHIN PLANTED AREAS AT THE SOIL LEVEL DIRECTLY BELOW THE MULCH LAYER. IV. POST-EMERGENT HERBICIDE (SELECTIVE AND NONSELECTIVE): EFFECTIVE FOR CONTROLLING WEED GROWTH THAT HAS ALREADY GERMINATED. B. GROUND PREPARATION I. THE PROJECT AREA SHALL HAVE THE PROPER TOPSOIL DEPTH SPREAD UNIFORMLY AND FINISH GRADES PER PLAN THROUGHOUT THE AREA BEFORE SEEDING COMMENCES. II. REMOVE ANY EXISTING STANDS OF EXISTING VEGETATION IN THE WORK AREA. USE OF AN APPROVED HERBICIDE TO TREAT ANY STANDS OF REED CANARY GRASS AND OTHER INVASIVE SPECIES PRIOR TO SEED INSTALLATION IS REQUIRED. A MINIMUM OF TWO HERBICIDE TREATMENTS WILL BE NECESSARY TO ACHIEVE CONTROL OF REED CANARY GRASS, ONCE IN THE FALL OF 2025 AND ANOTHER IN THE SPRING OF 2026. PRIOR TO SECOND TREATMENT IT WILL BE NECESSARY TO REMOVE DEAD GRASS FROM THE BUFFER AREA BY MANUAL MEANS OR CONTROLLED BURNING TO FACILITATE THE GERMINATION OF THE RCG SEEDBANK. III. TILL THE SITE WITH A PLOW, DISC, OR HARROW TO A MINIMUM DEPTH OF FOUR (4) INCHES AND TO A GREATER EXTENT NECESSARY TO BREAK UP ROOT SYSTEMS AND SOIL CLODS TO THE POINT WHERE THE AVERAGE CLUMP IS LESS THAN TWO (2) INCHES IN DIAMETER. REMOVE ALL STONES AND OTHER OBJECTS LARGER THAN ONE INCH (1”) IN THICKNESS OR DIAMETER INCLUDING ROOTS, BRUSH, WIRE, STAKES AND OTHER OBJECTIONABLE OBJECTS. IV. RAKE THE SOIL ON ALL SEEDED AREAS, BRINGING THE SOIL TO A SMOOTH, WELL DRAINED, EVENLY TEXTURED SURFACE CONFORMING TO THE GRADES SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL DO FINISH GRADING UNTIL THE SOIL IS IN A MELLOW CONDITION TO FINISH GRADE. ALL HOLES, DEPRESSIONS AND RIVULETS SHALL BE FILLED IN AND BROUGHT TO A SMOOTH GRADE TO ENSURE NO DISRUPTION OF ESTABLISHED DRAINAGE PATTERNS. V. GRADES SHALL BE CONSIDERED CRITICAL AND SHALL BE REVIEWED BY THE PROJECT MANAGER BEFORE SEEDING. 1 ZONE 1 A&B: -REMOVE AND TREAT ALL BUCKTHORN, HONEYSUCKLE AND JAPANESE KNOTWEED, SEE SPECIFICATIONS FOR REMOVALS AND TREATMENT INFORMATION. REMOVE ALL PLANT MATERIAL AND DISPOSE OF AT AN APPROPRIATE WASTE DISPOSAL SITE. removals key notes 2 ZONE 2: - TREAT AND REMOVE ALL JAPANESE KNOTWEED & REED CANARY GRASS. SEE SPECIFICATIONS FOR TREATMENT AND REMOVALS INFORMATION. REMOVE ALL PLANT MATERIAL AND DISPOSE OF AT AN APPROPRIATE WASTE DISPOSAL SITE. -SEED WITH WETLAND EDGE SEED MIX AND BLANKET PER SPECIFICATIONS. -PROVIDE WETLAND EDGE NATIVE PLUGS, 24" O.C. THROUGHOUT ENTIRE AREA. PLUG MIX PER SPECIFICATIONS. ZONE 3: - AREA OF GRAVEL REMOVAL, SEE CIVIL TO CONFIRM EXTENTS AND REMOVALS DEPTH. PLACE AND COMPACT MN DOT 3877-1 TOPSOIL. -SEED WITH MESIC PRAIRIE SEED MIX AND BLANKET PER SPECIFICATIONS. -PROVIDE MESIC NATIVE PLUGS, 24" O.C. THROUGHOUT ENTIRE AREA. PLUG MIX PER SPECIFICATIONS. REMOVE DEAD ASH: CUT TO GROUND AND GRUB OUT STUMP AND ROOTS. REMOVE WOOD AND DISPOSE AT AN APPROVED ASH DISPOSAL SITE PER MINNESOTA DEPARTMENT OF AGRICULTURE REQUIREMENTS. 3   L1.0 h :(7/$1' / / / /,1:22'$9( *2/)&2856( *2 / )  & 2 8 5 6 ( &, 7 <  2 )  6 7  3 $ 8 /  2 : 1 ( '  / 2 7 /           35 2 3 ( 5 7 <  / , 1 ( 35 2 3 ( 5 7 <  / , 1 ( 3523(57</,1( 3523(57</,1( %% %%%%7/ %% %% %% %% %%7/ 7/ (3 (3 (3 (3 (3 (3      :( 7 / $ 1 '   / / / / / 2(57(/ $5&+,7(&76/7' 6DLQW&ODLU$YHQXH SKRQH   6W3DXO0LQQHVRWD ZZZRHUWHODUFKLWHFWVFRP 6+((712 6+((71$0( 3/277(' 352-(&71$0( ,+(5(%<&(57,)<7+$77+,63/$1 63(&,),&$7,21255(3257:$6 35(3$5('%<0(2581'(50<',5(&7 683(59,6,21$1'7+$7,$0$'8/< /,&(16('$5&+,7(&781'(57+(/$:6 2)7+(67$7(2)0,11(627$ 6,*1$785( 5(9,6,216 35 2 - ( & 7  1 $ 0 (  1RWIRU&RQV W U X F W L R Q 127(6 &/,(17 &2168/7$17 /,&(16( '$7( '5$:1%< &+(&.('%< 352-(&7180%(5 '$7( ‹&23<5,*+72(57(/$5&+,7(&76$//5,*+765(6(59(' 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ '(%5$%5$1':,&.  30 / '%1) & /$1'6&$3( 3/$1 673$8/32/,&(75$,1,1*)$&,/,7<  67  3 $ 8 /  3 2 / , & ( 75 $ , 1 , 1 *  ) $ & , / , 7 <     / L Q Z R R G  $ Y H  (   0 D S O H Z R R G  01       &20081,7<'(6,*15(9,(:   /$1'6&$3(3/$1 /)=238)7 /)=:%09) /)=238)8)<8 0 1392( 0 7)48-'8%2/7 0 4638)'886))(6-40-2) 0 63'/190', 0 )(+)3**-6-2+0%2) 0  ;)80%2(7)8&%'/ /(*(1' (;,67,1*75(( 75((72%(5(029(' 1(:75(( 1257+               127(6 727$/(;,67,1*75((6 727$/75((672%(5(029('   5(3/$&(75((6:,7+0,1,080',$0(7(5 %8,/',1*1257+ 3/$17,1*6&+('8/( .(<&200211$0(6&,(17,),&1$0(6,=(47< 1R 'DWH 'HVFULSWLRQ (3 7/ %% ($67(51:+,7(3,1( 7$0$5$&. %/8(%($&+ 3,1866752%86 /$5,;/$5,&,1,$ &$53,186&$52/,1,$1$ ',$ ',$ ',$    L3.0 SEE TREE INVENTORY FOR FURTHER INFORMATION h :(7/$1'                  /,1:22'$9(18( *2 / )  & 2 8 5 6 ( *2/)&2856( &, 7 <  2 )  6 7  3 $ 8 /  2 : 1 ( '  / 2 7                3523(57</,1( 35 2 3 ( 5 7 <  / , 1 ( 35 2 3 ( 5 7 <  / , 1 ( 3523(57</,1(                                            :( 7 / $ 1 '          6)        2(57(/ $5&+,7(&76/7' 6DLQW&ODLU$YHQXH SKRQH   6W3DXO0LQQHVRWD ZZZRHUWHODUFKLWHFWVFRP 6+((712 6+((71$0( 3/277(' 352-(&71$0( ,+(5(%<&(57,)<7+$77+,63/$1 63(&,),&$7,21255(3257:$6 35(3$5('%<0(2581'(50<',5(&7 683(59,6,21$1'7+$7,$0$'8/< /,&(16('$5&+,7(&781'(57+(/$:6 2)7+(67$7(2)0,11(627$ 6,*1$785( 5(9,6,216 35 2 - ( & 7  1 $ 0 (  1RWIRU&RQV W U X F W L R Q 127(6 &/,(17 &2168/7$17 /,&(16( '$7( '5$:1%< &+(&.('%< 352-(&7180%(5 '$7( ‹&23<5,*+72(57(/$5&+,7(&76$//5,*+765(6(59(' 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ '(%5$%5$1':,&.  30 $ '%1) & 6,7(3/$1 673$8/32/,&(75$,1,1*)$&,/,7<  67  3 $ 8 /  3 2 / , & ( 75 $ , 1 , 1 *  ) $ & , / , 7 <     / L Q Z R R G  $ Y H  (   0 D S O H Z R R G  01       &20081,7<'(6,*15(9,(: 1257+   6,7(3/$1 /)=238)7 /)=:%09) /)=238)8)<8  2);86%-2-2+3**-')&9-0(-2+  )<-78-2+&9-0(-2+836)1%-2  )<-78-2+&9-0(-2+83&)()13)(  )<-78-2+6%2+)'%234=  )<-78-2+8%'8-'%07-190%8-32 7869'896)7  )<-78-2+'0%77:  )<-78-2+4%:)((6-:);%=  )<-78-2+%74,%08  2);%74,%08  2);'32'6)8)  %'')77-&0)4%6/-2+7-+2  6)13:)%2(6)40%') 3* ',%-20-2/*)2')*367)48-' %'')77  463437)(2);;)0003'%8-32  7)48-'*-)0(   ;)80%2(7)8&%'/   ;)80%2(7)8&%'/  ;)80%2(&392(%6=  0-1-873*'327869'8-32  )<-78-2+6%2+)7,)08)6  7)48-'8%2/7   ;)80%2(7)8&%'/  '96&%2(+988)6  463437)(*)2')0-2)               127(6 6) 3$5.,1*67$//60,1,080 $&&(66,%/(67$//6 $&&(66,%/(67$// %8,/',1*1257+ 1R 'DWH 'HVFULSWLRQ 6,*1$*( :(7/$1'6,*1 Galvanized posts Wetland Signage on fence - every 20' +/- In addition to signage required every 100' FENCE TYPE PROPOSED 726/$%   %2522)   72/2:(5522)   72833(5522)   +0'225 $1')5$0( (175< &$123< '2:163287 *877(5 $/80,180 6725()5217 %8//(75(6,67$17 '2:163287 )$6&,$ 6721(9(1((5 63/,7)$&( 6721(9(1((5 60227+ &21&5(7( 63/$6+3$' '2:163287 *877(5 $/80,180 6725()5217 %8//(75(6,67$17 )$6&,$                     726/$%   %2522)   72/2:(5522)   72833(5522)   '2:163287 *877(5 )$6&,$ 6721(9(1((5 63/,7)$&( 6721(9(1((5 60227+ $/80,180 6725()5217 '2:163287 *877(5 )$6&,$                       2(57(/ $5&+,7(&76/7' 6DLQW&ODLU$YHQXH SKRQH   6W3DXO0LQQHVRWD ZZZRHUWHODUFKLWHFWVFRP 6+((712 6+((71$0( 3/277(' 352-(&71$0( ,+(5(%<&(57,)<7+$77+,63/$1 63(&,),&$7,21255(3257:$6 35(3$5('%<0(2581'(50<',5(&7 683(59,6,21$1'7+$7,$0$'8/< /,&(16('$5&+,7(&781'(57+(/$:6 2)7+(67$7(2)0,11(627$ 6,*1$785( 5(9,6,216 35 2 - ( & 7  1 $ 0 (  1RWIRU&RQV W U X F W L R Q 127(6 &/,(17 &2168/7$17 /,&(16( '$7( '5$:1%< &+(&.('%< 352-(&7180%(5 '$7( ‹&23<5,*+72(57(/$5&+,7(&76$//5,*+765(6(59(' 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ '(%5$%5$1':,&.  $0 $ '%1) & %8,/',1* (/(9$7,216 673$8/32/,&(75$,1,1*)$&,/,7<  67  3 $ 8 /  3 2 / , & ( 75 $ , 1 , 1 *  ) $ & , / , 7 <     / L Q Z R R G  $ Y H  (   0 D S O H Z R R G  01       &20081,7<'(6,*15(9,(:   1257+(/(9$7,21   6287+(/(9$7,21 1R 'DWH 'HVFULSWLRQ   726/$%   %2522)   72/2:(5522)   72833(5522)   '2:1 63287 &/(5(6725< 75$16/8&(17 3$1(/6 $/80,180 6725()5217 $63+$/7 6+,1*/(6 6721(9(1((5 63/,7)$&( 6721(9(1((5 60227+ *877(5 :22' 62)),7 )$6&,$ (175<&$123< )$6&,$ '2:163287                       726/$%   %2522)   72/2:(5522)   72833(5522)   +0'225 $1')5$0( '2:163287 6721(9(1((5 63/,7)$&( 6721(9(1((5 60227+ *877(5 $63+$/76+,1*/(6 (175<&$123< &21&5(7( 63/$6+3$' *877(5 '2:163287 )$6&,$                     2(57(/ $5&+,7(&76/7' 6DLQW&ODLU$YHQXH SKRQH   6W3DXO0LQQHVRWD ZZZRHUWHODUFKLWHFWVFRP 6+((712 6+((71$0( 3/277(' 352-(&71$0( ,+(5(%<&(57,)<7+$77+,63/$1 63(&,),&$7,21255(3257:$6 35(3$5('%<0(2581'(50<',5(&7 683(59,6,21$1'7+$7,$0$'8/< /,&(16('$5&+,7(&781'(57+(/$:6 2)7+(67$7(2)0,11(627$ 6,*1$785( 5(9,6,216 35 2 - ( & 7  1 $ 0 (  1RWIRU&RQV W U X F W L R Q 127(6 &/,(17 &2168/7$17 /,&(16( '$7( '5$:1%< &+(&.('%< 352-(&7180%(5 '$7( ‹&23<5,*+72(57(/$5&+,7(&76$//5,*+765(6(59(' 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ '(%5$%5$1':,&.  $0 $ '%1) & %8,/',1* (/(9$7,216 673$8/32/,&(75$,1,1*)$&,/,7<  67  3 $ 8 /  3 2 / , & ( 75 $ , 1 , 1 *  ) $ & , / , 7 <     / L Q Z R R G  $ Y H  (   0 D S O H Z R R G  01       &20081,7<'(6,*15(9,(:   ($67(/(9$7,21   :(67(/(9$7,21 1R 'DWH 'HVFULSWLRQ   2(57(/ $5&+,7(&76/7' 6DLQW&ODLU$YHQXH SKRQH   6W3DXO0LQQHVRWD ZZZRHUWHODUFKLWHFWVFRP 6+((712 6+((71$0( 3/277('352-(&71$0( ,+(5(%<&(57,)<7+$77+,63/$1 63(&,),&$7,21255(3257:$6 35(3$5('%<0(2581'(50<',5(&7 683(59,6,21$1'7+$7,$0$'8/< /,&(16('$5&+,7(&781'(57+(/$:6 2)7+(67$7(2)0,11(627$ 6,*1$785( 5(9,6,216 35 2 - ( & 7  1 $ 0 (  1RWIRU&RQV W U X F W L R Q 127(6 &/,(17 &2168/7$17 /,&(16( '$7( '5$:1%< &+(&.('%< 352-(&7180%(5 '$7( ‹&23<5,*+72(57(/$5&+,7(&76$//5,*+765(6(59(' 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ 1RWIRU&RQVWUXFWLRQ '(%5$%5$1':,&.  $0 $ '%1) & %8,/',1* 5(1'(5,1*6 673$8/32/,&(75$,1,1*)$&,/,7<  67  3 $ 8 /  3 2 / , & ( 75 $ , 1 , 1 *  ) $ & , / , 7 <     / L Q Z R R G  $ Y H  (   0 D S O H Z R R G  01       &20081,7<'(6,*15(9,(: 1257+($679,(: 1257+:(679,(: 1R 'DWH 'HVFULSWLRQ   Engineering Plan Review PROJECT: Saint Paul Police Firearms Training Facility 2621 Linwood Avenue PROJECT NO: 25-13 COMMENTS BY: Jon Jarosch, Assistant City Engineer DATE: 4-2-2025 PLAN SET: Engineering plans dated 3-8-2025 The applicant is proposing to replace the existing classroom training facility at 2621 Linwood Avenue. In addition, the proposal includes replacing portions of the entrance drive and parking lot, the septic system, and the onsite well. This review does not constitute a final review of the plans, as the applicant will need to submit construction documents for final review prior to issuing permits. The following are engineering review comments on the design and act as conditions prior to issuing permits: Drainage and Stormwater Management 1)The applicant shall verify the total area disturbed by the project along with the total area of new impervious surfacing. Should the project exceed ½ acre of disturbance or add more than 5,000 square feet of new impervious surface, the project shall meet the City’s stormwater management standards. 2)Concrete curb and gutter is required around parking lots and entrance drives per City Code. The applicant shall include concrete curb and gutter along the parking lot edge and entrance drive. Water and Sewer Service 3)This project proposes the installation of a new well to provide potable water to the new classroom facility, as there is currently no water service available adjacent to this site. A housing development has been proposed at the adjacent Ponds at Battle Creek property. If this project is approved and moves forward, water main will be installed along Linwood Avenue to service the housing development. This water main could be utilized in lieu of installing a new well at the Saint Paul Police Firearms Training Facility. The applicant shall coordinate with the developer of the Ponds at Battle Creek site to determine whether or not connecting to the proposed water main is a viable solution. Attachment 7 4)This project proposes the installation of a new septic system to provide sewer service to the new classroom facility, as there is currently no sewer service available near this site. If the adjacent development at the Ponds at Battle Creek site moves forward, sanitary sewer mainline may be made available adjacent to this site. The applicant shall coordinate with the developer of the Ponds at Battle Creek site to determine whether or not connecting to the proposed sewer mainline is a viable solution. 5)A subsurface sewage treatment system (SSTS) permit is required for new septic systems. All requirements of the SSTS Ordinance shall be met for the proposed septic system. Grading and Erosion Control 6)Inlet protection devices shall be installed on all existing and proposed onsite storm sewer until all exposed soils are stabilized. 7)Public and private drives and roadways shall be swept as needed to keep the pavement clear of sediment and construction debris. 8)All pedestrian facilities shall be ADA compliant. 9)A copy of the project SWPPP and NDPES Permit shall be submitted prior to the issuance of a grading permit. 10)All slopes shall be 3H:1V or less steep in slope. 11)The total cut/fill volume shall be noted on the grading plan. Public Works Permits The following permits are required by the Public Works Department for this project. The applicant should verify the need for other City permits with the Building Department. 12)Grading and erosion control permit 13)SSTS Permit 14)Right-of-way Permit (If work is completed within Linwood Avenue right-of-way.) -END COMMENTS - 1 Environmental Review Project: St. Paul Police Training Facility Location: 2621 Linwood Avenue Date of Plans: March 18, 2025 and May 5, 2025 Date of Review: Updated Review May 15, 2025 Reviewer: Shann Finwall, Sustainability Coordinator (651) 249-2304, shann.finwall@maplewoodmn.gov Background: The St. Paul Police Department is proposing to upgrade their training facility at 2621 Linwood Avenue East. The development must comply with the tree and wetland ordinances, and landscape policies. Trees: 1.Tree Preservation Ordinance: a.Significant Trees: Maplewood’s tree preservation ordinance describes a significant tree as a healthy tree as follows - hardwood tree with a minimum of 6 inches in diameter, an evergreen tree with a minimum of 8 inches in diameter, and a softwood tree with a minimum of 12 inches in diameter. b.Specimen Trees: A specimen tree is defined as a healthy tree of any species which is 28 inches in diameter or greater. c.Tree Replacement: If less than 20 percent of the overall caliper inches of significant trees on the site are removed, applicants must replace one 2 diameter inch tree for each significant tree removed. If more than 20 percent are removed, replacement is based on the City’s tree replacement calculation which includes the overall caliper inches of significant trees located on the parcel versus the caliper inches of significant trees removed. Additionally, credits are given for all specimen trees that are preserved. 2.Tree Impacts: The tree survey identifies 308 significant trees on the site, however, the overall caliper inches of significant trees are not included. The site demolition plan shows the removal of 18 significant trees; however, the size and species of the trees are not included. Tree replacement cannot be determined without additional information, but it is likely that the tree removal is less than 20 percent of the overall caliper inches of trees on the site. In that case the required tree replacement is 18 – 2 diameter inch trees. 3.Tree Replacement: The landscape plan includes 18 – 2 diameter inch trees. Attachment 8 2 4. Tree Recommendations: a. Prior to issuance of a grading permit the following is required: 1) Tree Plan: a) Identify which trees will be removed on the tree survey and the size and species on the site demolition plan. b) Add the City’s tree replacement calculation to the plans. The tree calculation will include the overall caliper inches of significant trees on the site versus the caliper inches of trees removed. 2) Tree Planting Plan: Final tree planting plan to be reviewed and approved by the City’s Natural Resources Coordinator. 3) Tree Escrow: Tree escrow in the amount of $60 per caliper inch of trees to be replaced on the site. The escrow will be released once the trees are planted with a one-year warranty. Wetlands: 1. Wetland Ordinance: a. Wetland Classification and Buffer Requirements: There are two Manage A wetlands, one adjacent the property on the vacant lot to the west and one on the east side of the property. The City’s wetland ordinance requires a 75-foot minimum and 100-foot average wetland buffer around a Manage A wetland. b. Wetland Buffer Averaging: The wetland ordinance allows flexibility in instances where, because of the unique physical characteristics of a specific parcel of land, the averaging of buffer width for the entire parcel may be necessary to allow for the reasonable use of the land during a development or construction project. In such cases decreasing the minimum buffer width will be compensated for by increased buffer widths elsewhere in the same parcel to achieve the required average buffer width. \Averaging is allowed based on an assessment of the following: 1) Undue hardship would arise from not allowing the average buffer, or would otherwise not be in the public interest. 2) Size of parcel. 3) Configuration of existing roads and utilities. 4) Percentage of parcel covered by wetland. 5) Configuration of wetlands on the parcel. 3 6) Averaging will not cause degradation of the wetland or stream. 7) Averaging will ensure the protection or enhancement of portions of the buffer which are found to be the most ecologically beneficial to the wetland or stream. 8) A wetland buffer mitigation plan is required for construction of development projects that will require averaging. In reviewing the mitigation plan, the city may require one or more of the following actions: a) Reducing or avoiding the impact by limiting the degree or amount of the action, such as by using appropriate technology. b) Rectifying the impact by repairing, rehabilitating, or restoring the buffer. c) Reducing or eliminating the impact over time by prevention and maintenance operations during the life of the actions. d) Compensating for the impact by replacing, enhancing, or providing substitute buffer land at a two-to-one ratio. e) Monitoring the impact and taking appropriate corrective measures. f) Where the city requires restoration or replacement of a buffer, the owner or contractor shall replant the buffer with native vegetation. A restoration plan must be approved by the city before planting. g) Any additional conditions required by the applicable watershed district and/or the soil and water conservation district shall apply. h) A wetland or buffer mitigation surety, such as a cash deposit or letter of credit, of 150 percent of estimated cost for mitigation. The surety will be required based on the size of the project as deemed necessary by the administrator. Funds will be held by the city until successful completion of restoration as determined by the city after a final inspection. Wetland or buffer mitigation surety does not include other sureties required pursuant to any other provision of city ordinance or city directive. c. Wetland Buffer Variance: Any deviation from the wetland buffer or wetland buffer averaging requires a wetland buffer variance. The City may require the applicant to mitigate wetland buffer impacts with the 4 approval of a varian ce, including, but not limited to, implementing one or more of the strategies listed in the mitigation strategies above. 2.Wetland Impacts: a.Existing Conditions: The site was originally developed and graded in approximately 1975, prior to the City’s wetland ordinance and wetland buffer requirements. The drive lane, tactical training buildings, storage building, and gravel pad extend into the 100-foot wetland buffers and are considered pre-existing nonconforming structures and encroachments. b.New Development: The new development will have grading to within approximately 53 feet of the eastern Manage A wetland for the extension of a utility line, parking stall, and septic system. Grading will come to within approximately 59 feet of the western Manage A wetland for building earthwork. Other portions of the new development will be located within the 75-foot minimum buffer. The development requires a 41-foot wetland buffer variance, wetland buffer averaging, and wetland buffer mitigation as required by the wetland ordinance. 3.Proposed Wetland Mitigation: To mitigate the wetland buffer impacts the applicants are proposing a total of .15 acres of mitigation strategies to include the removal of buckthorn and other invasive species in key areas around the eastern wetland, removal of Class 5 surface adjacent the eastern wetland, establishment of a new 10-foot buffer with native plants and seeds along the east and north side of the eastern wetland, wetland buffer protection fence adjacent the remaining Class 5 surface, and wetland buffer signs around both wetlands. 4.Wetland Buffer Recommendations: a.Prior to issuance of a grading permit the following is required: 1)Fence plan to include the materials, height, and location. 2)Revised landscape plan to include: a)Detailed plan for nonnative plant removal and maintenance. b)Native seed mix to be installed in the area called out as Zone 1A in the May 5 restoration plan in addition to the proposed removal of the nonnative plants. c)Detailed plan for new wetland buffer including seed mix species and installation methods, and location and species of native plant plugs. d)Final landscape plan to be reviewed and approved by the Natural Resources Coordinator. 5 3) Wetland Buffer Sign Plan: Identify the location of wetland buffer signs to be installed along the approved wetland buffers. The signs should be placed every 25 feet on the east side of the Class 5 surface, adjacent the new wetland buffer and 100 feet in all other areas of the approved wetland buffer. The City of Maplewood supplies wetland buffer signs identifying that no building, mowing, or grading should take place within the buffer. There is a $35 fee per sign. 4) Wetland Buffer Sign Installation: Install the wetland buffer signs prior to grading if feasible 5) Wetland Buffer Mitigation and Maintenance Agreement: Sign a wetland buffer mitigation and maintenance agreement with the City requiring that the applicant establish and maintain the required mitigation within the buffer for a three-year period. The City of Maplewood will draft the maintenance agreement once the wetland buffer mitigation plan is complete. 6) Submit a cash escrow or letter of credit to cover 150 percent of the wetland buffer mitigation. The City will retain the escrow for up to three years as outlined in the maintenance agreement to ensure the wetland buffer mitigation is established and maintained. Landscape Policies and Recommendations: Landscape Policies: Review of the overall landscape plan to ensure nonnative and invasive species are avoided, seed mix is appropriate for use in areas proposed, and plantings are climate resilient. Landscape Recommendations: Prior to issuance of a grading permit the final landscape plan to be reviewed and approved by the City’s Natural Resources Coordinator. WETLAND BUFFER VARIANCE RESOLUTION BE IT RESOLVED by the City Council of the City of Maplewood, Minnesota, as follows: Section 1. Background. 1.01 The City of Saint Paul Police Department has requested a wetland buffer variance to build a new training facility on the property at 2621 Linwood Avenue East. 1.02 The property located at 2621 Linwood Avenue East is legally described as: The west 600 feet of the South 525 feet of the Southeast Quarter of the Southeast Quarter of Section 12, Township 28, Range 22, according to the plat thereof on file and of record in the office of the Register of Deeds in and for Ramsey County, Minnesota. PIN: 122822440002 1.03 The site was originally developed and graded in approximately 1975, prior to the City’s wetland ordinance and wetland buffer requirements. The drive lane, tactical training buildings, storage building, and gravel pad extend into the 100-foot wetland buffers and are considered pre-existing nonconforming structures and encroachments. 1.04 The new development requires a 41-foot wetland buffer variance, wetland buffer averaging, and wetland buffer mitigation as required by the wetland ordinance. The new development will have grading to within approximately 53 feet of the eastern Manage A wetland for the extension of a utility line, parking stall, and septic system. Grading will come to within approximately 59 feet of the western Manage A wetland for building earthwork. Other portions of the new development will be located within the 75-foot minimum buffer. Section 2. Standards. 2.01 Wetland Buffer Variance Standards. The City Ordinance states that the City Council must base approval of a variance on the following standards for approval. 1.Before the city council acts on a wetland ordinance variance, the Environmental and Natural Resources Commission and the Planning Commission will make a recommendation to the city council. The city shall hold a public hearing for the variance. The city shall notify property owners within 500 feet of the property for which the variance is being requested at least ten days before the hearing. 2.The city may require the applicant to mitigate any wetland, stream, or buffer alteration impacts with the approval of a variance, including, but not limited to, implementing one or more of the strategies listed in subsection 18-221(e)(4) (mitigation). 3.To approve a variance, the city council shall apply the findings for variance approval as required in Minnesota Statutes. Attachment 9 4.The applicant for a variance shall submit, with the variance application and any other required materials, a statement showing how the proposal would meet the findings for variance approval. Section 3. Findings. 3.01 The proposal meets the specific wetland buffer variance standards. Section 4. City Review Process 4.01 The City conducted the following review when considering this wetland buffer variance request. 1.On April 15, 2025, the Planning Commission held a public hearing. City staff published a hearing notice in the Pioneer Press and sent notices to the surrounding property owners. The Planning Commission allowed everyone to speak and present written statements at the hearing. The Planning Commission recommended that the City Council approve this resolution. 2.On May 19, 2025, the Environmental and Natural Resources Commission held a public meeting to discuss the proposal. The ENR recommended that the City Council _______ this resolution. 3.On June 9, 2025, the City Council discussed this resolution. They considered reports and recommendations from the planning commission and City staff. 2